US Home Energy Planner
What does your home need?
Free, about 2 minutes, no email. Start with the rebates for work you already have in mind, or build the full plan: what homes in your climate usually need, an upgrade plan with conservative heating and cooling savings at your state’s energy prices, the tests worth asking for, and the programs open where you live.
The planner runs in your browser. Nothing you enter is stored or sent anywhere.
What would you like help with?
Your free plan · a pre-audit estimate
Your home’s energy plan
Estimates end where the audit begins
Everything above is based on how homes like yours typically perform (scaled to your bills if you entered them), not a model of your actual house. A home energy audit, with a blower door test, a duct leakage test where the ducts run outside the living space, an infrared scan, combustion safety checks and, for new equipment, a Manual J load calculation, turns these ranges into numbers for your address. The federal $150 audit tax credit ended with 2025, but utility and state programs commonly pay for most or all of an assessment.
Our guide to finding an auditor → How an audit works → What an audit costs →
Want a person to look at your plan?
A person reads every message and replies with the auditors and utility programs that serve your area. We’ve started the form with your ZIP code, home type and a summary of this plan with its link; change anything you like. Nothing is sent until you press the button.
Estimates are ranges based on how similar homes perform: heating from building-science starting points for each era, cooling from EIA’s 2020 survey of US homes, your area’s climate (NOAA) and your state’s energy prices (EIA), with the assumptions listed below. They are deliberately conservative and are not a guarantee of savings. Program details change, so confirm on official pages before spending. Nothing you enter here is stored or sent anywhere: the planner runs entirely in your browser, and this page loads no analytics. Your answers sit only in this page’s address, so a link you copy carries them.
How the estimates work, and every assumption behind them
The first three digits of your ZIP code place the home in a state and, where we cover it, one of the 26 largest metro areas, using Census Bureau ZIP code areas, population and the 2023 metro definitions. The metro sets the climate: heating and cooling degree days from NOAA’s 1991–2020 normals at its main airport, and the climate profile that decides which problems, checks and wording fit. Outside those metros the planner uses the nearest covered metro in your state, or a stand-in you pick, and says so. Energy prices are your state’s averages from the U.S. Energy Information Administration (EIA). If you enter a gas, oil or propane bill, the heating estimate is scaled to it; if you enter a summer and a winter electric bill, they are split by degree days into air conditioning, heating and everything else, and the matching estimate is scaled to them (always within 0.5× to 1.6× of a typical house). An energy audit replaces all of this with measurements. Program and price data were checked on October 12, 2026; the cooling model on 2026-10-26.
| Built | Heat needed | Attic | Walls | Basement walls | Windows |
|---|---|---|---|---|---|
| Before 1946 | 88 kBtu per sq ft a year at 7,560 °F degree days | R-12 | R-4 | R-4 | single-pane with storm windows |
| 1946–1965 | 62 kBtu per sq ft a year at 7,560 °F degree days | R-12 | R-8 | R-4 | single-pane with storm windows |
| 1966–1980 | 53 kBtu per sq ft a year at 7,560 °F degree days | R-20 | R-12 | R-4 | double-pane, clear glass |
| 1981–1995 | 40 kBtu per sq ft a year at 7,560 °F degree days | R-28 | R-12 | R-12 | double-pane, clear glass |
| 1996–2010 | 35 kBtu per sq ft a year at 7,560 °F degree days | R-40 | R-17 | R-12 | double-pane, low-e |
| 2011 or later | 26 kBtu per sq ft a year at 7,560 °F degree days | R-50 | R-19 | R-20 | double-pane, low-e |
These are typical starting points for a house of each age, not measurements: building-science archetypes for the insulation, windows and air leakage of each era, the same ones our calculator engine uses across the site. US homes of the same age vary widely, and an audit measures yours. Heat needed is scaled to your climate’s degree days. Townhouses, rowhouses and duplexes use 90% of the detached figure, and the four size bands are modeled as about 1,000, 1,600, 2,500, 3,500 sq ft.
Heating: what the model assumes
- Heating need per square foot by era, house sizes and the starting insulation levels and windows above, scaled from NOAA 65 °F degree days (divided by 1.8 for the engine’s Celsius degree days).
- Upgrade physics: the R-value, window U-factor and air-leakage formulas, multiplied by 0.75 above grade and 0.4 for basement walls; no single upgrade credited with more than 35% of heating, and all together with no more than 60%. Air sealing is credited with a 20% cut in leakage, which is taken as 25% of heat loss.
- Equipment efficiencies: gas furnaces 80% and 95%, gas boilers 82% and 89%, oil 60–85%, propane 82% and 93%, electric resistance 100%, geothermal heat pumps a seasonal COP of 2.8. Air-source heat pumps have a seasonal COP (backup heat included) that falls as winters get colder: cold-climate models 2.8 below 5,400 °F heating degree days, down to 1.6 above 10,800. Heat pump upgrades are priced as cold-climate models where winters reach 4,000 heating degree days, standard models elsewhere.
- Hot water: about 20 gallons per person a day for a household of three, heated to 131 °F, with the cold-water temperature worked out from the degree days. Heat pump water heaters are charged for the heat they take from the house only during the heating share of the year (heating degree days as a share of all degree days, at most two-thirds), so in hot climates that charge is small.
- Thermostat setbacks save about 2% of heating per degree Celsius (1.8 °F) held for 8 hours; heat pumps limited to about 4 °F.
- Attic target: ENERGY STAR’s retrofit figure for an uninsulated attic in your IECC climate zone: R-30 in zone 1, R-49 in zones 2–3 and R-60 in zones 4–8.
- Units: therms (natural gas converted at EIA’s 1,036 Btu per cubic foot), gallons, kilowatt-hours and US dollars. Propane water heaters are given the model’s gas tank efficiency.
Cooling and bills: what the model assumes
- Air conditioning: EIA’s 2020 Residential Energy Consumption Survey (RECS) microdata for single-family detached homes with central AC, indoor fan included, one benchmark per metro (its state and climate cell), rescaled to the metro’s normal cooling degree days (exponent 0.9 in humid and dry zones, 0.5 in marine ones), the home’s size (exponent 0.6), era (from ×1.15 before 1946 to ×0.8 since 2011) and type (townhouses ×0.75, condos ×0.57). Window units use RECS figures per household by zone. The typical range runs from 0.7× to 1.35× (0.5× to 1.6× in marine climates).
- AC efficiency by age, from federal standards and LBNL shipment data: a central AC under 10 years old about SEER 14.8 in the South (where federal minimums are higher) and 14.05 elsewhere; 10 years or more, about SEER 13.5 in houses built since 1996 and 12.06 in older ones; heat pumps about SEER 14.59 under 15 years and 12.22 over. A new variable-speed unit is about SEER 18 (17.1 SEER2).
- Cooling savings, as a share of the AC estimate (typical, from NREL ResStock and Florida Solar Energy Center field studies): duct sealing 12% where ducts run through an attic or crawlspace; a radiant barrier 8% over thin insulation; a cool roof 10%; window film or solar screens 7% and low-SHGC windows 15% on clear glass; air sealing up to 4–5% by zone; attic insulation by a formula on the before and after R-values; raising the cooling setting by the metro’s share per degree. Measures combine without double counting: attic insulation, a radiant barrier and a cool roof overlap, so the largest counts in full and the others at half.
- Electric bills: a two-bill degree-day split, a two-point version of the billing analysis in DOE’s Uniform Methods Project, using NOAA’s monthly normals. It falls back to the typical house, and says why, when the months’ weather is too similar, the summer bill isn’t higher, or the non-heating, non-cooling use comes out outside 5–60 kWh a day.
- Prices: EIA state averages, shown with the month or week they cover, and U.S. averages, labeled national, where EIA has no state figure. Savings are valued at these averages, which include fixed charges, so they can run a little high.
- Left out: crawlspace savings, installed costs and paybacks (we don’t have reliable US prices for them yet), and pools, EVs and other large loads.
Energy prices by state (EIA, as used by the planner)
| State | Electricity, July 2026 | Natural gas, 2025 average | Heating oil, week of October 5, 2026 | Propane, week of October 5, 2026 |
|---|---|---|---|---|
| Alabama | 16.4¢/kWh | $1.69/therm | none published; U.S. $6.04 used | $3.52/gal |
| Alaska | 28.8¢/kWh | $1.25/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Arizona | 15.4¢/kWh | $1.79/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Arkansas | 14.3¢/kWh | $1.86/therm | none published; U.S. $6.04 used | $2.29/gal |
| California | 33.6¢/kWh | $2.12/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Colorado | 17.0¢/kWh | $1.08/therm | none published; U.S. $6.04 used | $2.39/gal |
| Connecticut | 24.2¢/kWh | $1.62/therm (2024 average; no 2025 figure) | $6.00/gal | $4.21/gal |
| Delaware | 18.5¢/kWh | $1.54/therm | $6.04/gal | $3.67/gal |
| District of Columbia | 25.2¢/kWh | $1.61/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Florida | 15.0¢/kWh | $2.46/therm | none published; U.S. $6.04 used | $4.86/gal |
| Georgia | 16.3¢/kWh | $1.97/therm | none published; U.S. $6.04 used | $3.08/gal |
| Hawaii | 48.0¢/kWh | $5.06/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Idaho | 13.7¢/kWh | $0.74/therm | none published; U.S. $6.04 used | $2.51/gal |
| Illinois | 19.2¢/kWh | $1.09/therm | none published; U.S. $6.04 used | $1.83/gal |
| Indiana | 16.7¢/kWh | $1.11/therm | $5.76/gal | $2.47/gal |
| Iowa | 16.0¢/kWh | $1.02/therm | $5.68/gal | $1.63/gal |
| Kansas | 15.3¢/kWh | $1.43/therm | none published; U.S. $6.04 used | $2.01/gal |
| Kentucky | 13.8¢/kWh | $1.37/therm | $5.83/gal | $2.67/gal |
| Louisiana | 12.7¢/kWh | $1.68/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Maine | 32.4¢/kWh | $1.83/therm (2024 average; no 2025 figure) | $5.97/gal | $3.55/gal |
| Maryland | 21.4¢/kWh | $1.56/therm (2024 average; no 2025 figure) | $6.11/gal | $3.80/gal |
| Massachusetts | 30.5¢/kWh | $2.42/therm | $6.12/gal | $3.59/gal |
| Michigan | 23.1¢/kWh | $1.05/therm | $5.58/gal | $2.34/gal |
| Minnesota | 17.4¢/kWh | $1.06/therm | $5.74/gal | $1.90/gal |
| Mississippi | 14.5¢/kWh | $1.61/therm | none published; U.S. $6.04 used | $3.05/gal |
| Missouri | 16.1¢/kWh | $1.44/therm | none published; U.S. $6.04 used | $2.06/gal |
| Montana | 15.0¢/kWh | $0.87/therm | none published; U.S. $6.04 used | $1.91/gal |
| Nebraska | 13.8¢/kWh | $1.10/therm | $5.33/gal | $1.70/gal |
| Nevada | 12.8¢/kWh | $1.27/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| New Hampshire | 26.6¢/kWh | $1.80/therm | $5.98/gal | $3.95/gal |
| New Jersey | 25.2¢/kWh | $1.37/therm | $6.04/gal | $3.95/gal |
| New Mexico | 16.1¢/kWh | $0.95/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| New York | 29.9¢/kWh | $1.70/therm | $6.23/gal | $3.67/gal |
| North Carolina | 15.2¢/kWh | $1.58/therm (2024 average; no 2025 figure) | $5.82/gal | $3.58/gal |
| North Dakota | 13.4¢/kWh | $0.92/therm | none published; U.S. $6.04 used | $1.61/gal |
| Ohio | 19.4¢/kWh | $1.34/therm | $5.92/gal | $2.57/gal |
| Oklahoma | 14.3¢/kWh | $1.39/therm | none published; U.S. $6.04 used | $2.29/gal |
| Oregon | 16.0¢/kWh | $1.61/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Pennsylvania | 21.7¢/kWh | $1.45/therm | $5.83/gal | $3.15/gal |
| Rhode Island | 28.3¢/kWh | $2.09/therm (2024 average; no 2025 figure) | $6.12/gal | $3.82/gal |
| South Carolina | 15.5¢/kWh | $1.63/therm (2024 average; no 2025 figure) | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| South Dakota | 15.4¢/kWh | $0.95/therm | none published; U.S. $6.04 used | $1.73/gal |
| Tennessee | 13.7¢/kWh | $1.14/therm | none published; U.S. $6.04 used | $3.19/gal |
| Texas | 15.9¢/kWh | $1.87/therm | none published; U.S. $6.04 used | $3.10/gal |
| Utah | 13.1¢/kWh | $0.98/therm | none published; U.S. $6.04 used | $2.23/gal |
| Vermont | 23.8¢/kWh | $1.74/therm | $5.99/gal | $3.77/gal |
| Virginia | 17.6¢/kWh | $1.62/therm | $5.95/gal | $3.68/gal |
| Washington | 14.7¢/kWh | $1.70/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| West Virginia | 15.8¢/kWh | $1.33/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| Wisconsin | 19.1¢/kWh | $1.04/therm | $5.58/gal | $1.81/gal |
| Wyoming | 14.4¢/kWh | $1.13/therm | none published; U.S. $6.04 used | none published; U.S. $2.60 used |
| United States (national) | 18.3¢/kWh | $1.48/therm | $6.04/gal | $2.60/gal |
Electricity: EIA Electric Power Monthly, residential average for July 2026 (released September 24, 2026). Natural gas: EIA residential price, 2025 annual average, which is steadier than a summer month; EIA calls it inclusive of taxes and delivery charges. Heating oil and propane: EIA weekly residential prices for the week of October 5, 2026, excluding taxes; EIA publishes them for some states only, and the planner leaves those fuels out where there’s no local price unless your home uses them.
Climate and air conditioning in the 26 metro areas (NOAA 1991–2020 normals, EIA RECS 2020)
| Metro area | Heating degree days | Cooling degree days | IECC zone | AC, typical home | Station |
|---|---|---|---|---|---|
| Minneapolis–St. Paul | 7,399 | 830 | 6A | about 1,400 kWh a year | MINNEAPOLIS/ST PAUL AP, MN US |
| Detroit | 6,067 | 847 | 5A | about 1,500 kWh a year | DETROIT METRO AP, MI US |
| Chicago | 5,974 | 1,003 | 5A | about 1,700 kWh a year | CHICAGO OHARE INTL AP, IL US |
| Denver | 5,862 | 850 | 5B | about 1,500 kWh a year | DENVER INTL AP, CO US |
| Boston | 5,545 | 802 | 5A | about 1,700 kWh a year | BOSTON LOGAN INTL AP, MA US |
| New York City | 4,872 | 1,017 | 4A | about 2,200 kWh a year | NEW YORK JFK INTL AP, NY US |
| Philadelphia | 4,510 | 1,358 | 4A | about 2,500 kWh a year | PHILADELPHIA INTL AP, PA US |
| Baltimore | 4,484 | 1,322 | 4A | about 2,100 kWh a year | BALTIMORE WASH INTL AP, MD US |
| St. Louis | 4,433 | 1,713 | 4A | about 3,100 kWh a year | ST LOUIS LAMBERT INTL AP, MO US |
| Seattle | 4,376 | 265 | 4C | about 1,000 kWh a year | SEATTLE TACOMA INTL AP, WA US |
| Portland | 4,104 | 508 | 4C | about 1,400 kWh a year | PORTLAND INTL AP, OR US |
| Washington, DC | 3,769 | 1,738 | 4A | about 2,900 kWh a year | WASHINGTON REAGAN AP, VA US |
| Charlotte | 3,058 | 1,769 | 3A | about 3,200 kWh a year | CHARLOTTE DOUGLAS AP, NC US |
| Atlanta | 2,531 | 2,051 | 3A | about 3,500 kWh a year | ATLANTA HARTSFIELD INTL AP, GA US |
| San Francisco | 2,475 | 200 | 3C | about 600 kWh a year | SAN FRANCISCO INTL AP, CA US |
| Dallas–Fort Worth | 2,220 | 2,824 | 2A | about 4,500 kWh a year | DALLAS FT WORTH AP, TX US |
| Austin | 1,718 | 2,996 | 2A | about 4,900 kWh a year | AUSTIN BERGSTROM AP, TX US |
| San Antonio | 1,438 | 3,148 | 2A | about 5,100 kWh a year | SAN ANTONIO INTL AP, TX US |
| Riverside | 1,386 | 1,854 | 3B | about 2,400 kWh a year | RIVERSIDE MUNI AP, CA US |
| Greater Houston | 1,266 | 3,288 | 2A | about 5,300 kWh a year | HOUSTON INTERCONT AP, TX US |
| Los Angeles | 1,214 | 720 | 3B | about 1,000 kWh a year | LOS ANGELES INTL AP, CA US |
| San Diego | 990 | 893 | 3B | about 1,300 kWh a year | SAN DIEGO LINDBERGH FLD, CA US |
| Phoenix | 874 | 4,765 | 2B | about 6,700 kWh a year | PHOENIX SKY HARBOR INTL AP, AZ US |
| Orlando | 525 | 3,452 | 2A | about 4,400 kWh a year | ORLANDO INTL AP, FL US |
| Tampa | 434 | 3,928 | 2A | about 5,000 kWh a year | TAMPA INTL AP, FL US |
| Miami | 104 | 4,656 | 1A | about 9,200 kWh a year | MIAMI INTL AP, FL US |
Degree days are base 65 °F. Metros are listed coldest first. “AC, typical home” is the model’s yearly air conditioning for a 1,600 sq ft detached house built 1981–1995 with an average central AC.
Sources
- NOAA NCEI U.S. Climate Normals 1991–2020: heating and cooling degree days
- U.S. Census Bureau, Vintage 2025 population estimates, Metropolitan Statistical Areas (July 1, 2025): the 26 metro areas
- EIA Electric Power Monthly, Table 5.6.A · EIA residential natural gas prices (annual) · EIA heat content of natural gas · EIA Heating Oil and Propane Update
- ENERGY STAR - Recommended Home Insulation R-Values: attic and floor targets by climate zone
- EIA 2020 Residential Energy Consumption Survey (RECS), public microdata
- EIA RECS 2020 end-use table CE5.3a
- NREL ResStock 2024 release 2 documentation
- Florida Solar Energy Center: duct repair in occupied homes
- Florida Solar Energy Center: attic radiant barriers
- Florida Solar Energy Center: cool roofs
- Florida Solar Energy Center: windows and solar heat gain
- Building America Solution Center: attic radiant barriers
- DOE Uniform Methods Project, chapter 8: whole-building (bill) analysis
- NOAA 1991–2020 monthly degree-day normals
- Federal AC and heat pump efficiency standards (10 CFR 430.32)
- LBNL Home Energy Saver: equipment efficiency by year
- EIA residential equipment technology assumptions (Appendix A)
- NREL: heat pump water heaters and the space they sit in
- U.S. Census Bureau, 2020 ZCTA to County Relationship File (national): which counties each 2020 ZIP Code Tabulation Area (ZCTA) touches, with the land area of each part
- U.S. Census Bureau, Core Based Statistical Areas (CBSAs), Metropolitan Divisions and Combined Statistical Areas, July 2023 delineation file (List 1, OMB Bulletin 23-01)
- U.S. Census Bureau, American Community Survey 2020-2024 5-year estimates, table-based summary file, table B01003 (total population), ZCTA rows
- U.S. Census Bureau, 2020 Gazetteer file for ZCTAs (internal point latitude and longitude), used for distances to the nearest covered metro
- U.S. Census Bureau, state FIPS codes and USPS abbreviations (state.txt)