Energy test guide · verified October 2, 2026

Thermal imaging: seeing the empty walls without opening them

An infrared camera maps the temperature of every surface, and temperature tells stories: missing insulation reads as cold streaks, thermal bridges as dark ribs, hidden moisture as blotches that don't match the framing. It's the difference between guessing which walls are empty and photographing it.

Hands holding an infrared camera aimed at a ceiling corner beside a frosty window; the screen shows a cold streak

Cost

Usually included — confirm

Best conditions

≥10°C in/out difference

Finds

Empty walls, bridges, moisture

Pairs with

Blower door running

What's involved

  1. Get the conditions right

    IR needs a temperature difference of about 10°C or more between inside and out — a cold morning is perfect, and direct sun on a wall ruins the reading for hours. This is why winter audits produce the best imagery, and why a good advisor scans early or on overcast days.

  2. Scan room by room from inside

    Exterior walls, ceilings below attics, around windows and doors, behind furniture on outside walls, basement rim joists. Each frame is a temperature map of the assembly behind the drywall.

  3. Run it during the blower door

    With the house depressurized, leaking air chills the surfaces along its path — leaks light up as cold streams the camera sees and the hand alone would miss. The combination is the audit's most powerful diagnostic.

  4. Read the patterns

    Uniform wall = insulated. Striped cold bays between warm studs = empty or slumped cavity insulation. Cold ribs at every stud = thermal bridging. Irregular blotches that ignore the framing pattern = possible moisture — which gets verified with a moisture meter, not assumed.

  5. Keep the images

    The photos scope the fix precisely (which walls to drill-and-fill, which attic zones are thin) and the after-scan proves the contractor actually filled what they were paid to fill.

A 1950s brick bungalow on a snowy suburban street at dusk, lamplight in the front window
The same bungalow as an infrared camera sees it: heat glowing around the door, window frames, eaves and the rim joist above the foundation
Illustration: the same house in visible light and in infrared. On a cold night the scan lights up where heat escapes: door and window edges, the eaves, and the rim joist above the foundation.

How to get it done

Most registered advisors include a thermal scan with the assessment — confirm when booking, since it's the item most worth asking for by name. Building-science contractors also scan standalone. Phone-clip IR cameras are a fun screening tool, but their resolution suits finding suspects, not proving scope.

If it finds a problem: your remediation options

The scan's findings map to three different fixes — and one warning:

Commonly $2–$5 / sq ft

Drill-and-fill wall insulation

Empty frame walls get dense-packed with cellulose through small holes, patched after. The scan tells the contractor exactly which bays — and the after-scan proves the fill.

$1,500–$3,500 typical

Attic top-up (after air sealing)

Thin or wind-washed attic zones the ceiling scan reveals — see the attic inspection guide for the seal-first sequence.

Folded into renos

Thermal-bridge and detail fixes

Cold ribs and corners are framing geometry — fixed economically only when siding, cladding, or interior renovations open that assembly anyway. Until then, they're a known quantity, not an emergency.

The warning: moisture-pattern findings mean find the water first — roof, plumbing, grading, or condensation — before any insulation goes in. Insulating a wet assembly locks the problem in. That diagnosis path is the mold & indoor air guide's territory.

Cost figures are Ontario planning bands as of October 2, 2026 — quotes vary with the house; use them to budget, not to negotiate.

Common questions

Can the camera see through walls?

No — it reads surface temperature only. The skill is inference: knowing what a healthy assembly's surface should look like at these conditions, and what empty bays, bridging, air leaks, and moisture each do to that pattern. That's why conditions and operator experience matter more than camera price.

Does it work in summer?

It can — a hot attic or air-conditioned interior can provide the needed temperature difference, and duct leaks show well in cooling season. But Canadian winters offer bigger, more reliable deltas, which is one more reason not to postpone an audit to spring.

My phone IR attachment found a cold spot. Now what?

Treat it as a lead, not a verdict. Low-resolution cameras find suspects; the advisor's scan under proper conditions (ideally with the blower door running) confirms whether it's missing insulation, an air leak, a bridge, or just a cold water pipe.

Get the scan with your assessment

We'll match you with a registered advisor and flag thermal imaging in your request — the add-on most worth confirming by name.

Email us what you’re planning, your postal code and the type of building (a house, a duplex or triplex, or a larger multi-unit building) — we’ll reply with registered service organizations for your area and which rebates apply.

Email dave@clickshift.ca