Worst-case depressurization test

Also called: worst-case depressurization · worst-case test · worst-case CAZ test · CAZ depressurization test

A combustion safety check run with exhaust fans on and doors set to create the lowest pressure the furnace room is likely to see.

What it means

The auditor closes windows and exterior doors, turns on exhaust fans, the dryer and sometimes the furnace blower, and sets interior doors to make the combustion appliance zone (CAZ) as depressurized as possible. Each appliance is then fired to check its draft, spillage and carbon monoxide. If venting fails only under these conditions, fixes can include make-up air, smaller exhaust fans or replacing natural-draft appliances.

Why it matters in an audit

It reveals backdrafting risks that a normal check would miss, which is why it's done before and after major air sealing.

In the United States

Pass limits depend on how the appliance is vented and on the standard used, such as BPI-1200 or RESNET's CAZ procedure.