Combustion safety test

Also called: combustion safety testing · combustion safety check · CAZ test · CAZ testing · combustion appliance test

A check that furnaces, boilers, water heaters and stoves burn cleanly and vent their exhaust outside, even with fans running.

What it means

The auditor measures carbon monoxide (CO) in the flue and in the room, checks the draft in the chimney or vent and looks for spillage or backdrafting. The toughest version, a worst-case depressurization test, turns on exhaust fans and closes doors to see if venting still works. It's done before and after air sealing because a tighter house leaves less air for fuel-burning appliances.

Why it matters in an audit

It protects your household from carbon monoxide, and a failed test becomes a must-fix item ahead of any energy upgrade.

Typical numbers

Reference values with their sources. Your auditor’s report gives the figure for your own house.

What Value Source
US EPA outdoor CO standard (NAAQS) 9 ppm (8-hour average); 35 ppm (1-hour average) epa.gov ↗
Typical CO in US homes without gas stoves (EPA) 0.5–5 ppm epa.gov ↗

In the United States

Many US auditors follow test procedures and pass/fail limits in BPI's ANSI/BPI-1200 standard.