Glossary · Heating, cooling & ventilation

Air-source heat pump (ASHP)

Also called: air-source heat pumps · air-to-air heat pump

A heat pump that takes heat from outdoor air in winter and releases heat outdoors in summer, using an outdoor unit with a fan.

What it means

An outdoor unit with a fan and compressor connects by refrigerant lines to an indoor coil in your ductwork or to wall-mounted heads (see ductless mini-split). Its efficiency and capacity drop as outdoor temperatures fall, and it runs short defrost cycles in cold, damp weather. Cold-climate models keep heating efficiently well below freezing.

Why it matters in an audit

Choosing the right model for your climate, sizing it with a load calculation and planning auxiliary heat decide how much it will actually save.

Typical numbers

Reference values with their sources. Your auditor’s report gives the figure for your own house.

What Value Source
Efficiency, NRCan COP typically 2.0–5.4 at 46°F (8°C); 1.1–3.7 at 18°F (−8°C) natural-resources.canada.ca ↗
Low-temperature limit, NRCan Newer models' minimum operating temperatures range from 5°F to −13°F (−15°C to −25°C) natural-resources.canada.ca ↗
US federal minimum (2023) Split: SEER2 14.3, HSPF2 7.5; single-package: SEER2 13.4, HSPF2 6.7 www1.eere.energy.gov ↗
ENERGY STAR (heat pump spec 6.2, rev. Feb 2026) Split: SEER2 ≥ 15.2, EER2 ≥ 11.0, HSPF2 ≥ 7.8; single-package: SEER2 ≥ 15.2, EER2 ≥ 10.0, HSPF2 ≥ 7.2 energystar.gov ↗

Sources