Glossary · Heating, cooling & ventilation
Air-source heat pump (ASHP)
Also called: air-source heat pumps · air-to-air heat pump
A heat pump that takes heat from outdoor air in winter and releases heat outdoors in summer, using an outdoor unit with a fan.
What it means
An outdoor unit with a fan and compressor connects by refrigerant lines to an indoor coil in your ductwork or to wall-mounted heads (see ductless mini-split). Its efficiency and capacity drop as outdoor temperatures fall, and it runs short defrost cycles in cold, damp weather. Cold-climate models keep heating efficiently well below freezing.
Why it matters in an audit
Choosing the right model for your climate, sizing it with a load calculation and planning auxiliary heat decide how much it will actually save.
Typical numbers
Reference values with their sources. Your auditor’s report gives the figure for your own house.
| What | Value | Source |
|---|---|---|
| Efficiency, NRCan | COP typically 2.0–5.4 at 46°F (8°C); 1.1–3.7 at 18°F (−8°C) | natural-resources.canada.ca ↗ |
| Low-temperature limit, NRCan | Newer models' minimum operating temperatures range from 5°F to −13°F (−15°C to −25°C) | natural-resources.canada.ca ↗ |
| US federal minimum (2023) | Split: SEER2 14.3, HSPF2 7.5; single-package: SEER2 13.4, HSPF2 6.7 | www1.eere.energy.gov ↗ |
| ENERGY STAR (heat pump spec 6.2, rev. Feb 2026) | Split: SEER2 ≥ 15.2, EER2 ≥ 11.0, HSPF2 ≥ 7.8; single-package: SEER2 ≥ 15.2, EER2 ≥ 10.0, HSPF2 ≥ 7.2 | energystar.gov ↗ |