Brand guide · Canada · checked October 19, 2026

ACiQ heat pumps

ACiQ is made by 1HVAC (Troy, Ohio), which lists ACiQ under 'Our Brands'. ENERGY STAR lists 148 ACiQ outdoor models certified for Canada, 109 of them cold-climate, and its best certified pairing heats at a COP of 2.60 at −15°C (5°F).

Certified for Canada 148 outdoor models 8,054 certified pairings
Cold-climate 109 models meet ENERGY STAR Cold Climate; 109 meet NRCan's −15°C numbers on paper
Best COP at −15°C (5°F) 2.60 best HSPF2 14.8 · best SEER2 28.1
Warranty in Canada Not published see terms below

ACiQ at a glance

Who owns it
1HVAC (Troy, Ohio), which lists ACiQ under 'Our Brands'. The ENERGY STAR partner for ACiQ mini-splits is '1HVAC Energy, LLC' and ACiQ's warranty address is 250 Northwoods Blvd, Vandalia, Ohio. Carrier makes the ducted split systems (see manufacturing). No ownership link to Ferguson was found, and no 2024-2026 ownership change was found.
Sister brands
STEALTH, DIYCOOL, PolarWave, InfinityLiving
Headquarters
Troy, Ohio, USA
Where it's made
Ducted AC and heat pump condensers: Carrier's International Comfort Products. The ACiQ condenser warranty is issued by ICP, 'A Carrier Company', and ENERGY STAR lists Carrier Corporation as the certifying partner for thousands of ACiQ split-system combinations. Plant location not stated. Mini-split maker not disclosed.
How it's sold
Contractors and online
Price tier
Budget. ACiQ states its mission as 'high-quality and high value heating and cooling to the public' and sells through online retailers (HVAC Direct, Amazon, OnlineSupply and others) with published prices. No price survey was cited.
What it makes
ductless mini-split, multi-zone, ducted mini-split, ducted central, packaged
Names on ENERGY STAR's list
1HVAC, ACiQ (certified by 1HVAC Energy, LLC; Carrier Corporation)

Product lines

The current residential heat pump lines we found on ACiQ's own pages, with the low-temperature claim in the maker's words. 2 of 7 are sold as cold-climate.

ACiQ heat pump lines
LineTypeCold-climateMaker's low-temperature claimRefrigerant
High-Efficiency Extreme Heat Series (inverter central heat pump) ducted central Yes extracting heat in temperatures as low as -22 °F; Efficient heating range of -22° – 75°F R-454B
Extreme (Extreme Heat) mini-split, single and multi-zone ductless mini-split Yes No low-temperature figure published —
Standard mini-split, single and multi-zone ductless mini-split No No low-temperature figure published —
Essentials mini-split ductless mini-split No No low-temperature figure published —
Traditional R454B Heat Pumps ducted central No No low-temperature figure published R-454B
High-Efficiency Top Discharge Inverter Heat Pump R32 ducted central No No low-temperature figure published R-32
Heat Pump Packaged Units packaged No No low-temperature figure published —

Certified models with the best cold-weather numbers

From ENERGY STAR's list for Canada (updated October 19, 2026): each row is one outdoor unit with its best certified pairing. 99 of 148 ACiQ outdoor models use R-454B or R-32; the tables show those.

Mini-splits and multi-splits (63 models)

ACiQ Mini-splits and multi-splits with the best ratings at −15°C (5°F)
Outdoor / indoor model Size Heat at −15°C (5°F) COP at −15°C (5°F) HSPF2 SEER2 Refrigerant AHRI #
ACIQ-24ZS-HP230C ACIQ-24W-HH-MD ACIQ Series 25,000 BTU/h 2-ton 19,600 BTU/h 78% of rated 2.54 11.7 23.0 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471560
ACIQ-12ZS-HP230C ACIQ-12FM-HH-MD ACIQ Series 12,000 BTU/h 1-ton 8,900 BTU/h 74% of rated 2.50 11.0 24.6 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471570
EZ-18ZPL-HP230B EZ-18W-MB EZ Series 18,000 BTU/h 1.5-ton 12,800 BTU/h 71% of rated 2.44 11.5 22.5 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 216980890
ACIQ-06ZPL-HP230C SCC-0609-HH-MB ACIQ Series 7,400 BTU/h 0.5-ton 8,100 BTU/h 110% of rated 2.40 12.0 22.0 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 216032292
ACIQ-18ZS-HP230C ACIQ-18CD-HH-MC ACIQ Series 20,000 BTU/h 1.5-ton 14,200 BTU/h 71% of rated 2.40 11.3 20.0 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471567
ACIQ-09ZS-HP230C ACIQ-09W-HH-MD ACIQ Series 10,000 BTU/h 1-ton 8,000 BTU/h 80% of rated 2.36 12.5 25.8 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471572

Central (ducted) split systems (89 models)

ACiQ Central (ducted) split systems with the best ratings at −15°C (5°F)
Outdoor / indoor model Size Heat at −15°C (5°F) COP at −15°C (5°F) HSPF2 SEER2 Refrigerant AHRI #
N5H8T36*K*AAA* FTMA5B60L0D* 2-STAGE 18 SEER HP 37,600 BTU/h 3-ton 18,600 BTU/h 50% of rated 2.48 8.5 17.0 R-454B 216631656
N5H8T60*K*AAA* EVM5X61M24A* 2-STAGE 18 SEER HP 60,000 BTU/h 4.5-ton 31,600 BTU/h 53% of rated 2.34 8.5 16.0 R-454B 216631529
N5H9V48*K*AAA* FTMA5B60L0D* Performance 19 SEER2 VS HP 48,000 BTU/h 4-ton 36,000 BTU/h 75% of rated 2.32 10.0 19.0 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218020919
N5H8T48*K*AAA* FTMA5B60L0D* 2-STAGE 18 SEER HP 48,500 BTU/h 4-ton 24,600 BTU/h 51% of rated 2.32 8.1 18.0 R-454B 215561906
ACIQ-18ZS-HP230C ACIQ-18AHB-HH-MB ACIQ Series 18,000 BTU/h 1.5-ton 13,000 BTU/h 72% of rated 2.30 9.8 18.5 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471559
R5H5S48*K*AAA* F5MA5*60L*D* 15 SEER2 HP 46,500 BTU/h 4-ton 24,400 BTU/h 53% of rated 2.30 7.8 15.2 R-454B 216629118

Most efficient for cooling

ACiQ systems with the highest SEER2
Outdoor / indoor model Size SEER2 EER2 HSPF2 COP at −15°C (5°F) Refrigerant AHRI #
ACIQ-09ZPL-HP230C ACIQ-09W-HH-MD ACIQ Series 12,000 BTU/h 1-ton 27.4 15.4 12.5 1.80 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 216032268
ACIQ-09ZS-HP230C ACIQ-12FM-HH-MD ACIQ Series 9,000 BTU/h 1-ton 26.0 16.2 13.9 2.27 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471576
ACIQ-06ZPL-HP230C ACIQ-06W-HH-MD ACIQ Series 7,000 BTU/h 0.5-ton 25.5 18.0 14.8 2.39 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 216032267
ACIQ-12ZS-HP230C ACIQ-12W-HH-MD ACIQ Series 12,000 BTU/h 1-ton 25.5 13.0 10.6 2.30 R-454B ENERGY STAR Cold Climate Meets NRCan's −15°C thresholds 218471568

Look up any pairing by its AHRI number in the AHRI Directory ↗ or search the model in ENERGY STAR's product finder ↗. Ratings are for the exact indoor and outdoor pairing shown.

Warranty

In Canada Not published
For comparison: in the US 7-year parts, 12-year compressor

Mini-split and High-Efficiency systems: 5 years parts / 7 years compressor, starting from the purchase date. Essentials: 3/5 years (4/6 if registered). ICP-issued AC/heat pump condensers: 5 years parts instead of 10.

ACiQ didn't publish warranty terms for Canada on any page we could read on October 19, 2026. Get the warranty in writing with your quote.

Strengths and watch-outs

Strengths

  • Ducted systems built by Carrier: the ICP condenser warranty is marked 'A Carrier Company', and Carrier Corporation is the ENERGY STAR partner for ACiQ split systems
  • Long registered mini-split warranty: 12 years compressor / 7 years parts
  • Cold-climate inverter ducted option: Extreme Heat series rated for heating down to -22°F (maker claim)
  • Buy online at published prices or through authorized dealers

Watch-outs

  • ACiQ's own warranty requires the whole system to be 'installed, serviced, and diagnosed by an EPA-certified technician' and installed in the US, so DIY installs and Canadian installs fall outside it
  • Register within 90 days of installation; otherwise coverage drops and runs from the purchase date. Labour is never reimbursed.
  • Multiple R-410A ACiQ systems are still listed on ENERGY STAR and on ACiQ's central heat pump page. Confirm a current A2L model and that it can legally be installed.
  • No Canadian retailers or dealers are listed

Which rebates ACiQ models fit

109 ACiQ outdoor models meet the cold-climate numbers NRCan publishes for its Eligible Products List (COP of at least 1.8 at −15°C at full output, 70% of rated capacity, a variable-speed compressor) on their ENERGY STAR ratings. That list decides Ontario's Home Renovation Savings rebate, Manitoba's, New Brunswick's, Yukon's and Newfoundland and Labrador's, and the federal National Heat Pump Rebate expected in early 2027. Check the exact pairing on NRCan's list ↗.

109 models meet ENERGY STAR Cold Climate, which earns Quebec's higher LogisVert rate. BC uses its own qualified list. Rebate rules by province:

Get quotes for ACiQ or a comparable heat pump

Tell us about your home and what you want to heat. We match you with one heating and cooling contractor or registered energy advisor who serves your area and knows the rebates.

We use these details only to answer this request. Privacy