How Cambridge is built
- Before 1961 23%
- 1961–1990 37%
- 1991–2000 16%
- 2001 or later 24%
What inspections find in Cambridge attics
Of Cambridge's 41,030 houses (single-detached, semi-detached, row houses and duplexes), 23% were built before 1961 and 60% before 1991, according to the 2021 Census. Attics in older houses commonly have a fraction of today's recommended insulation, and top-ups done over the years often buried air leaks instead of sealing them first.
Cambridge gets about 3,664 heating degree-days a year and has a winter design temperature of −18.3°C, according to NRCan's HOT2000 climate data for Toronto International, the closest comparable location in that data set (63 km away). That's about 7% less heating demand than the middle of the 70 cities we cover. The colder the climate, the faster added attic insulation pays for itself.
Vermiculite. Loose, pebbly, grey-brown or silver-gold insulation may contain asbestos. Health Canada's advice is not to disturb it; have it sampled before any attic work. Asbestos and vermiculite testing in Cambridge
The right order for the work
- Seal the air leaks first: top plates, pot lights, plumbing stacks, the hatch.
- Fix ventilation baffles so new insulation doesn't block soffit vents.
- Then top up the insulation. Burying unsealed leaks under new insulation wastes much of the benefit.
NRCan-licensed service organizations serving Cambridge
Every EnerGuide evaluation includes an attic inspection: insulation depth, air leaks and red flags such as vermiculite or knob-and-tube wiring.
Only assessments from the seven HRSP-approved organizations qualify for the $600 Home Renovation Savings rebate and its assessment-path upgrade rebates; each listing below says whether it's one of them.
- Acacia Engineering HRSP-approved: No
- All Season Inspection HRSP-approved: No Profile
- AmeriSpec HRSP-approved: Yes Profile
- BEST Energy and Sustainability HRSP-approved: No
- Capital Home Energy HRSP-approved: No
- Clean Energy Solutions HRSP-approved: No
- EnerQuality HRSP-approved: No
- EnerSolution HRSP-approved: No Profile
- EnviroCentre HRSP-approved: No
- ER Energy Solutions HRSP-approved: No
- F2 Energy HRSP-approved: No
- GETS Energy HRSP-approved: No
- Green Canada Home Advisors HRSP-approved: No Profile
- Green Think HRSP-approved: No
- Greenbrain HRSP-approved: Yes Profile
- Isle Energy Consulting HRSP-approved: No
- MAP Energy HRSP-approved: No
- Reep Green Solutions HRSP-approved: No Non-profit network Profile
- Sensible Home Inspections HRSP-approved: No
- The Energuy HRSP-approved: Yes Profile
- Verdatech Energy Management and Consulting HRSP-approved: No
- Enerhold Engineering Solutions HRSP-approved: No
- Ecostep Energy Services HRSP-approved: No
- Energy Werx HRSP-approved: Yes Profile
- CoEfficient Building Science HRSP-approved: No
Insulation programs in Cambridge
Attic insulation inspection in Cambridge: common questions
How much attic insulation should a Cambridge house have?
Advisors commonly target around R-50 to R-60 in attics. Your EnerGuide report gives the recommendation for your house.
Can I top up the insulation myself?
Only after the air leaks are sealed and you've confirmed there is no vermiculite. The inspection tells you both.
Will more insulation stop ice dams?
Insulation helps, but ice dams are mostly caused by warm air leaking into the attic. Air sealing is the bigger fix.