Glossary · Heating, cooling & ventilation

COP (coefficient of performance)

Also called: COP at 5°F · heating COP

Heat delivered divided by electricity used at a given moment; a COP of 3 means three units of heat for each unit of electricity.

What it means

Electric baseboards and furnaces turn electricity into heat one-for-one, so their COP is about 1. Heat pumps reach COPs of 2 to 5 in mild weather because they move heat instead of making it, but COP falls as the outdoor temperature drops. Seasonal ratings such as HSPF average this over a whole winter.

Why it matters in an audit

COP at cold temperatures, such as −15°C (5°F), shows how cheaply a heat pump will run in your coldest weather and helps find the economic balance point against gas or oil.

Typical numbers

Reference values with their sources. Your energy advisor’s report gives the figure for your own house.

What Value Source
Air-source heat pumps (NRCan) 2.0–5.4 at 8°C; 1.1–3.7 at −8°C natural-resources.canada.ca ↗
Ground-source heat pumps (NRCan) About 3 in the coldest months; minimum 3.1 closed loop, 3.6 open loop natural-resources.canada.ca ↗
ENERGY STAR Cold Climate minimum 1.75 at 5°F (−15°C) energystar.gov ↗