Glossary · Testing & air leaks

Blower door test

Also called: blower door · air leakage test · airtightness test · depressurization test · fan door test

A test that uses a powerful, calibrated fan in an outside doorway to pull air out of the house and measure how leaky it is.

What it means

The auditor seals the fan into an exterior door frame and lowers the indoor air pressure, so outside air rushes in through every crack and gap. The fan's airflow at a standard pressure of 50 pascals (see 50 Pa) gives the home's leakage as CFM50 or ACH50. While the fan runs, the auditor can find leaks with a smoke pencil or infrared (thermal) imaging, and a repeat test after air sealing shows how much was fixed.

Why it matters in an audit

It turns 'my house feels drafty' into a number you can compare and set targets for, and it helps size heating and cooling equipment and decide whether the home needs mechanical ventilation.

Typical numbers

Reference values with their sources. Your energy advisor’s report gives the figure for your own house.

What Value Source
Standard test pressure 50 Pa (about 0.2 inch of water column) energycodes.gov ↗

In Canada

Canadian EnerGuide evaluations usually include a blower door test. NRCan's R-2000 Standard measures airtightness using the CAN/CGSB-149.10 method.