How Moncton is built
- Before 1961 24%
- 1961–1990 37%
- 1991–2000 12%
- 2001 or later 28%
Why it matters in Moncton
In the Moncton area, 34% of households heat mainly with electric baseboards; electricity is the main heating energy for 42% of households (Statistics Canada, 2023).
The risk rises after air sealing: a tighter house plus a strong exhaust fan or dryer can pull exhaust back down a chimney. That's why advisors test for spillage during an evaluation and why it should be repeated after serious tightening.
The CO alarm rule in New Brunswick
We found no New Brunswick rule requiring CO alarms in existing homes; new construction follows the 2020 National Building Code.
What the check involves
- Worst-case depressurization: exhaust fans and the dryer on, doors set to make the appliance room as negative as it gets.
- A spillage and draft check at each appliance, with a CO reading.
- A plan if anything fails: often a sealed-combustion appliance or a fix to the venting, done by a licensed gas or oil technician.
NRCan-licensed service organizations serving Moncton
Energy advisors check for combustion spillage during an evaluation; fixing a venting problem is work for a licensed gas or oil technician.
- Enercheck Solutions
- Homesol Building Solutions
- RU-Green Energy Solutions
- ThermalWise Green Building Cooperative
Programs in Moncton
Combustion safety test in Moncton: common questions
Are CO alarms required in Moncton homes?
We found no New Brunswick rule requiring CO alarms in existing homes; new construction follows the 2020 National Building Code.
Who does combustion safety testing?
Energy advisors check for spillage during an EnerGuide evaluation. Repairs to venting or appliances are done by a licensed gas or oil technician.
I have CO alarms. Isn't that enough?
Alarms warn you once CO is already in the house. A spillage test finds a venting problem before it produces CO.