How Fredericton is built
- Before 1961 23%
- 1961–1990 43%
- 1991–2000 11%
- 2001 or later 23%
Why it matters in Fredericton
In the Fredericton area, 31% of households heat mainly with a heat pump and 30% with electric baseboards; electricity is the main heating energy for 43% of households (Statistics Canada, 2023).
The risk rises after air sealing: a tighter house plus a strong exhaust fan or dryer can pull exhaust back down a chimney. That's why advisors test for spillage during an evaluation and why it should be repeated after serious tightening.
The CO alarm rule in New Brunswick
We found no New Brunswick rule requiring CO alarms in existing homes; new construction follows the 2020 National Building Code.
What the check involves
- Worst-case depressurization: exhaust fans and the dryer on, doors set to make the appliance room as negative as it gets.
- A spillage and draft check at each appliance, with a CO reading.
- A plan if anything fails: often a sealed-combustion appliance or a fix to the venting, done by a licensed gas or oil technician.
NRCan-licensed service organizations serving Fredericton
Energy advisors check for combustion spillage during an evaluation; fixing a venting problem is work for a licensed gas or oil technician.
- Enercheck Solutions
- Homesol Building Solutions
- RU-Green Energy Solutions
- ThermalWise Green Building Cooperative
Programs in Fredericton
Combustion safety test in Fredericton: common questions
Are CO alarms required in Fredericton homes?
We found no New Brunswick rule requiring CO alarms in existing homes; new construction follows the 2020 National Building Code.
Who does combustion safety testing?
Energy advisors check for spillage during an EnerGuide evaluation. Repairs to venting or appliances are done by a licensed gas or oil technician.
I have CO alarms. Isn't that enough?
Alarms warn you once CO is already in the house. A spillage test finds a venting problem before it produces CO.