Full-load hours (equivalent full-load hours)

Also called: EFLH

The number of hours a heating or cooling system would have to run flat out to deliver a whole season's heating or cooling.

What it means

Real equipment cycles on and off and often runs below full output, so energy calculators turn a season's demand into an equivalent number of hours at full capacity. NRCan's air conditioner cost formula does this with cooling degree-days: 24 × cooling degree-days ÷ (summer design temperature − 18°C). Multiply the full-load hours by the unit's capacity and divide by its efficiency to estimate the energy it uses.

Why it matters in an audit

It's how a calculator turns your local climate into a yearly kWh estimate for an air conditioner or heat pump: the more full-load hours, the more a high-efficiency unit saves.

Typical numbers

Reference values with their sources. Your energy advisor’s report gives the figure for your own house.

What Value Source
NRCan cooling formula (base 18°C) Full-load hours = 24 × cooling degree-days ÷ (summer outdoor design temperature − 18) natural-resources.canada.ca ↗
Worked example 200 cooling degree-days and a 30°C design temperature: 24 × 200 ÷ 12 = 400 full-load hours Arithmetic