How Calgary is built
- Before 1961 10%
- 1961–1990 38%
- 1991–2000 17%
- 2001 or later 36%
Why it matters in Calgary
In the Calgary area, 74% of households heat mainly with a forced-air furnace and 8% with a boiler and radiators; natural gas is the main heating energy for 73% of households and electricity for 13% (Statistics Canada, 2023).
The risk rises after air sealing: a tighter house plus a strong exhaust fan or dryer can pull exhaust back down a chimney. That's why advisors test for spillage during an evaluation and why it should be repeated after serious tightening.
The CO alarm rule in Alberta
Alberta requires CO alarms in new homes with a fuel-burning appliance or attached garage; for existing homes the province calls them highly recommended rather than mandatory.
What the check involves
- Worst-case depressurization: exhaust fans and the dryer on, doors set to make the appliance room as negative as it gets.
- A spillage and draft check at each appliance, with a CO reading.
- A plan if anything fails: often a sealed-combustion appliance or a fix to the venting, done by a licensed gas or oil technician.
NRCan-licensed service organizations serving Calgary
Energy advisors check for combustion spillage during an evaluation; fixing a venting problem is work for a licensed gas or oil technician.
- Acacia Engineering
- All Season Inspection Profile
- AmeriSpec Profile
- Buildingexpert
- Clean Energy Solutions
- CoEfficient Building Science
- Energy Werx Profile
- EnerHome Consulting
- EnerQuality
- EnerSolution Profile
- EnerVision
- GETS Energy
- Green Canada Home Advisors Profile
- Green Think
- Isle Energy Consulting
- Map Energy
- Sensible Home Inspections
- The Energuy Profile
- VerdaTech Energy Management and Consulting
- Enerspec Energy Consulting and Home Inspections
- Homesol Building Solutions
- NRGwise (A1 NRGwise Consulting) Profile
- Air Barrier Canada
- Greenbrain Profile
- Enerhold Engineering Solutions
- The Home Inspectors Group Profile
Combustion safety test in Calgary: common questions
Are CO alarms required in Calgary homes?
Alberta requires CO alarms in new homes with a fuel-burning appliance or attached garage; for existing homes the province calls them highly recommended rather than mandatory.
Who does combustion safety testing?
Energy advisors check for spillage during an EnerGuide evaluation. Repairs to venting or appliances are done by a licensed gas or oil technician.
I have CO alarms. Isn't that enough?
Alarms warn you once CO is already in the house. A spillage test finds a venting problem before it produces CO.