Natural-draft (atmospherically vented) appliance
Also called: atmospheric vent · draft hood · natural-draft water heater · natural-draft furnace
A furnace, boiler or water heater that takes combustion air from the room and relies on hot exhaust rising up a chimney, so house pressure can reverse it.
What it means
These appliances, including many older furnaces and standard gas water heaters, have an opening called a draft hood and depend on the chimney's natural draft to carry exhaust away. If exhaust fans, a dryer or a fireplace depressurize the house, or the chimney is cold or blocked, exhaust can spill back indoors. CMHC warns against pairing a natural-draft furnace with a powerful kitchen exhaust fan.
Why it matters in an audit
Natural-draft appliances are the ones most likely to backdraft, so auditors test them before and after air sealing and may suggest a sealed-combustion replacement.
Typical numbers
Reference values with their sources. Your energy advisor’s report gives the figure for your own house.
| What | Value | Source |
|---|---|---|
| Testing (DOE Building America) | Natural-draft furnaces, boilers and water heaters need combustion safety testing, including a spillage check at the draft hood with exhaust fans running | basc.pnnl.gov ↗ |